Evaluate pressure monitoring system regularly for air bubble formation and remove if present. Continuously observe the CVP waveform quality on the monitor and record variances to ensure the accuracy of the waveform and to detect changes in the patient's hemodynamic status.
A normal CVP waveform has a, c, and v waves. Evaluate the intra-arterial pressure monitoring system regularly for air bubble formation, which can lead to potentially lethal air emboli.
Remove air emboli by flushing through a system stopcock. Obtain baseline data including vital signs, level of consciousness, and hemodynamic stability to help identify acute changes in the patient.
Ensure that pt is still while CVP reading is being taken — measure at end expiration. If CVP fluctuates by more than 2mm Hg suspect change in clinical status and report. Read the CVP value by measuring the mean of the a wave at end expiration.
Document the patient's position for zeroing the transducer so that other health care team members can replicate the placement. Document dressing, tubing, flush solution changes, or discontinuation of line when appropriate. Central venous pressure monitoring, transducer. Transducer system setup. Pittman, J. B Arterial and central venous pressure monitoring. Anesthesiology Clin, 24 4 , Rauen, C. Evidence-based practice habits: Transforming research into bedside practice.
Critical Care Nurse 29 2 , You have unlimted attempts. Click to Start Exam. We are required to delay the exam until you have had time to view the course material. Please view the course first! Central Venous Pressure. Monitoring Central venous pressure is considered a direct measurement of the blood pressure in the right atrium and vena cava.
CVP reflects the amount of blood returning to the heart via the venous system and the ability of the heart to pump the blood into the arterial system. Record any redness or abnormal findings in the AI record and report to the physician. Central venous lines should be secured to avoid movement. Catheter movement can lead to inflammation at the site and migration of pathogens along the catheter tract.
Monitor Site Monitor site q 15 minutes following insertion, then q 1 h. Monitor for bleeding, IV connections and occlusivity of dressing. Monitor distal extremity for color, sensation, swelling and movement q 1 h. Document any finding not within normal limits in AI record. Bulky dressings can mask bleeding. Pressure dressings will not stop arterial bleeding.
Venous thrombosis or hematoma can compromise circulation to distal limb. Prevent Air Embolism Maintain luer-lock con nections on all central venous devices. Avoid piggybacking infusions that are not running on another infusion pump into Y sites that are located below the air detection devices.
When air venting is required for intracardiac shunt, ensure that air vent filters are placed below the most distal Y injection port. Infusions pumps have air detectors up to the level of the pump. Patients with intracardiac shunts are at increased risk for venous to arterial air embolization and require 0. Trendelenburg positioning and breath holding techniques are used during insertion and removal of central venous catheters to prevent air entry.
If air inadvertently enters a central venous catheter, immediately aspirate from the line and place the patient left side down in a trendelenburg position. Venous air embolism can create an "air lock" that blocks the flow of blood from the right side to the left side of the heart, leading to cardiorespiratory collapse.
CPR can break air into smaller bubbles to restore circultation. If venous air is broken into smaller bubbles or there is a persistent formen ovale, air can enter the left side and embolize to the brain or other organs.
Left lateral trendelenburg positioning may trap air bubbles within the right ventricle in an emergency. Strategies that increase cardiac pressures above atmospheric pressure reduce the gradient for air to move into the central venous catheter e.
Conversely, condition that lower intracardiac pressures in relation to atmospheric pressure increase the gradient for air entry into the catheter site upright positioing or hypotension. Measure right atrial and femoral venous pressures from a waveforms that is printed and analyzed to identify the pressure at end-expiration and the downslope base of the "V" wave. Waveform analysis is identified on a paper recording for each right atrial pressure measurement. Place paper recording in the clinical record with the CVP measurement point identified on the printout.
CVP measurements are obtained from a right atrial waveform. Femoral venous pressures do not reflect the right atrial pressure, but should have a waveform that is similar to a CVP.
The pressures from the femoral vein will be different, however, pressure trends from the femoral vein can provide guidance reqarding fluid resuscitation. The goal for right atrial pressure monitoring is to identify the pressure during end-expiration and end-diastole. Although the pre-C wave best reflects the end-diastolic pressure, it is often difficult to identify, reducing inter-rater reliability.
For consistency, we measure the pressure during mid-diastole during diastasis because it is easy to find and reflects a pressure that is similar to the pressure at end-diastole. Posting the waveform in the clinical record allows other members of the team to compare multiple pressure readings with better precision, allowing for more accurate interpretation of trends and signficance.
Refer to documentation standards. Identify CVP as per item 8 and document pressure in the graphic record. Post a printed waveform to the chart.
Assess catheter patency and document in the intravascular line section of the flow sheet at the start of each shift and q 4 h. To identify complications including: pneumothorax, hemothorax, hydrothorax, catheter kinking, catheter placement e. Exceptions may be made by the CCTC Consultant if the risk of line insertion exceeds the risk of infection. Central TPN supports the growth of infection, particularly fungemias. Introducers are used as stand alone IVs e.
An introducer is a central venous catheter and should be treated with the same central line insertion, maintenance and removal precautions e. Dressing occlusivity is more difficult to maintain when a central venous catheter is inserted through an introducer, especially at the jugular site. A "waterfall technique" where each lumen of the central venous catheter is taped separately may reduce the dressing "pull down" effect.
Background: Measurements of central venous pressure are generally obtained through one of the three ports of centrally placed triple-lumen catheters. However, no scientifically based literature is available that guides clinical practice and indicates which of the lumens is most appropriate for obtaining these measurements. Objective: To determine if a difference exists between measurements of central venous pressure obtained via the proximal, medial, and distal ports of a triple-lumen catheter.
Methods: Measurements of central venous pressure in 48 adult ICU patients were obtained via each of the three ports of a triple-lumen catheter.